Scinor

in

Scinor® SMT600–P40
TIPS
Datasheet: P40
Datasheet: SMT600-P40
Pressurized Ultrafiltration Module
Diagram Pressurized Ultrafiltration Module

Scinor SMT600 series ultrafiltration modules utilizing our state-of-the-art Thermally Induced Phase Separation (TIPS) PVDF membranes provide the highest permeability, mechanical
strength, and chemical tolerance in the industry. These modules are ideal for use in potable water, wastewater, desalination, and industrial applications. The SMT600-P50 retrofits major
membrane vendor installations giving end-users a choice when replacing membranes.

The SMT600-P50 is an outside-in configuration module that operates in dead-end or cross-flow mode depending on specifics of the application. Cleaning processes used are simple backwash, maintenance clean, and Clean-in-Place.

PRODUCT ADVANTAGES

Excellent Filtered Water Quality
• Tight 0.1 μm pore size distribution
• Low fiber breakage rate
Long Operational Life
• High mechanical strength and durability
• >5000 mg/L Sodium Hypochlorite tolerance
Low Capital Cost
• High flux rates on all water sourcess

 

Low Requirements for Pretreatment
• Outside-in configuration
• Optimal flow channel
Low Operating and Maintenance
Requirements

• Low energy and chemical consumption due to higher permeability
• Automatic operation

Retrofit modules available for all major membrane suppliers
ISO 9001 ISO 14001
SPECIFICATIONS
Module Specications Part Number SMT600-P40
Category Hollow Fiber/Outside-In
Material PVDF
Manufacturing Process TIPS
Nominal Pore Size 0.1 μm
I.D./O.D. 0.7 mm/1.3mm
Geometry 160mm x 1804mm
Housing/Head Material U-PVC/ABS
Potting Material Epoxy Resin
Sealing Type O-Ring/EPDM
A/B/C Port Size DN32, Union
Effective Area 431 ft2 (40 m2)
Module Volume (Water) 6.6 gallons (25 Liters)
Weight (With Water/Empty) 97/42 lb (44/19 kg)
Packing Weight 82 lb (37 kg)
Application & Operating Parameters Temperature Range 33 – 104F (1-40?)
pH Range During Operation 1-11
Max NaClO Tolerance 5,000 ppm
CIP pH Range 1-13
Typical Flux 20–120 gfd (34-200 lmh)
Typical Trans-Membrane Pressure 3–22 psi (0.02-0.15 Mpa)
Typical Backwash Flux 30-70 gfd (50-120 lmh)
Typical Air Scour Capacity 3.1-7.5 scfm (5-12 Nm3/h) module
Max Air Inlet Pressure 36 psi (0.25 Mpa)
Max Feed Pressure 58 psi (0.4 Mpa)
Max Trans-Membrane Pressure 44 psi (0.3 Mpa)
Max Backwash Pressure 36 psi (0.25 Mpa)
Typical Filtered Water Capacity 5.9-35.2 gpm/module
Filtered Water
Performance
Turbidity ≤0.1 ntu
Silt Density Index ≤3
E.Coli Removal non-detect
About Us Products Applications
Drinking Water
Wastewater
Desalination
Industrial
Direct Retrofit Service TIPS Fundamentals Contact Us

Scinor Water America, LLC
1440 Broadway, 23rd Floor
New York, NY 10018
800.774.1385
info@scinor.com | scinor.com

P23
P38
P40
P50
P51
P56
P72
P80
S26
S30
S50
Site Map | Privacy Policy © 2015 Scinor Water America, LLC | All Rights Reserved